REPLACEMENT
HINT: A bolt without a torque specification is shown in the standard bolt chart (see page 03-2 ).
1. REMOVE AIR CLEANER ASSY
2. REMOVE VVT SENSOR
(a) Disconnect the sensor connector.
(b) Remove the bolt and sensor.
3. INSTALL VVT SENSOR
(a) Apply a light coat of engine oil to a new O-ring. Install the O-ring onto the sensor.
(b) Install the sensor with the bolt.
Torque: 8.0 NVm (82 kgfVcm, 71 in.Vlbf) (c) Connect the sensor connector.
4. INSTALL AIR CLEANER ASSY (See page 14-24 )
Starting system (2AZ-FE)
INSPECTION
1. INSPECT STARTER ASSY
NOTICE:
These tests must be performed within 3 to 5 seconds to
avoid burning out the coil.
(a) Do the pull-in test.
Disconnect the lead wire from terminal C.
Connect the battery to the magnetic switch as
shown in the illustration on the ...