1. INSPECT THERMOSTAT
HINT: The valve opening temperature is stamped on the thermostat.
(a) Immerse the thermostat in water and gradually heat the water.
(b) Check the valve opening temperature.
Valve opening temperature: 80 to 84 C (176 to 183 F)
If the valve opening temperature is not as specified, replace the thermostat.
(c) Check the valve lift.
Valve lift: 10 mm (0.39 in.) or more at 95 C (203 F)
If the valve lift is not as specified, replace the thermostat.
(d) Check that the valve is fully closed when the thermostat is at low temperatures (below 77 C (171 F)).
If not closed, replace the thermostat.
2. INSPECT RADIATOR CAP SUB-ASSY
NOTICE:
(a) Using a radiator cap tester, slowly pump the tester and check that air is being released from the vacuum valve.
Pump speed: 1 push every 3 seconds or more
NOTICE: Push the pump at a constant speed.
If air is not being released from the vacuum valve, replace the reservoir cap.
(b) Pump the tester and measure the relief valve opening pressure.
Pump speed: 1 push within 1 second
NOTICE: The specified pump speed should be followed for the first pump only. It will close the vacuum valve. Once the vacuum is closed, the pump speed can be reduced.
Standard opening pressure: 93 to 122 kPa (0.95 to 1.25 kgf/cm2, 13.4 to 17.6 psi) Minimum opening pressure: 78 kPa (0.8 kgf/cm2, 11.4 psi)
HINT: Use the tester's maximum reading as the opening pressure. If the maximum reading is less than the minimum opening pressure, replace the radiator cap.
Intake air control valve ASSY NO.2 (3MZ-FE)
REPLACEMENT
1. REMOVE INTAKE AIR CONTROL VALVE ASSY NO.2
(a) Remove the 3 bolts and nut.
(b) Turn the lever to the closed position as shown in the illustration
and pull out the IAC valve.
(c) Remove the gasket from the intake air surge tank.
2. INSTALL INTAKE AIR CONTROL VALVE ASSY NO.2
( ...